Temperature Drop Test
Thermal Insulation Flooring Block
Test : Determination of temperature drop across the insulation
Test method : The specimen is kept on the hot plate at specified temperature and other surfaces are kept open to atmosphere. Once steady state is achieved, the temperatures of hot plate, top and bottom surfaces of specimen are measured using temperature sensors. The temperature drop is calculated as difference of top and bottom surface temperature.
Specimen details : Thermal Insulation Flooring Block
Thermal Insulation Flooring Block is a composite material made from Cement, Fly Ash and Expanded Clay Aggregate (ECA®)
Test Results :
Hot plate temperature °C | Top surface temperature °C | Bottom surface temperature °C | Temperature drop °C |
71.09 | 63.39 | 44.59 | 18.8 |